Enclosures of the series – GUB and GUBX are flameproof enclosures and meet the requirements of Directive 2014/34/EU, EN 60079-0:2012/A11:2013 have type of protection “d” according to EN 60079-1:2014 and “t” according to EN 60079- 31:2014, are intended for the installation of electrical equipment in places with the risk of an explosive environment. The shells can have various configuration options, providing reliable protection for built-in devices, terminals, devices, wires, etc.P.from external influence. The presented shells are the best solution for the subsequent assembly of finished equipment. On the outer surface of the shell there may be cable glands, drainage devices, controls, viewing windows, etc. d.
Explosion-proof enclosures differ in case design, overall dimensions, case material, presence of a viewing window.
The equipment mounted on the basis of the presented explosion-proof enclosures allows it to be classified as electrical equipment of groups I, II and III, belongs to the category 2M (mining version), 2G (gas environments), 3D (field environments). Equipment can be placed in zones 2, 3, 21 and 22. The environment may contain explosive mixtures of gases and vapors with air of category IIA, IIB and IIC, as well as IIIA (combustible flying particles), IIIB (non-conductive dust) and IIIC (conductive dust).
The shells are made of the following materials: GUB – copper-free aluminum alloy, GUBX – stainless steel. According to the manufacturing technology, the shells are divided into cast and welded.
Finished equipment based on shells can correspond to the following temperature class: T6, T5, T4, T3. When choosing a temperature class, consider the power dissipation of the enclosure, the operating temperature and the equipment used as accessories.
When mounting electrical equipment inside the shells, the following conditions must be observed that at least 40% of the cross-sectional area of \u200b\u200bthe shell remains free, for the unhindered flow of the gas flow, so as not to limit the development of the explosion.
Table 1.
Application area | Material | Name of shells | Ex marking according to EN 60079-0:2012/A11:2013 |
For group II and III | Copper-free aluminum alloy; Stainless steel |
GUB and GUBX |
II 2G Ex db IIC T6, T5, T4, T3 Gb; III 2D Ex tb IIIC T80 °C, T95 °C, T130 °C, T190 °C Gb. |
For group I and III | Stainless steel | GUBX |
I 2M Ex db I Mb; III 2D Ex tb IIIC T80 °C, T95 °C, T130 °C, T190 °C Gb. |
GUB and GUBX |
||
Housing material |
Copper-free aluminum alloy; Stainless steel. |
|
Ex marking |
II 2G Ex db IIC T6, T5, T4, T3 Gb; III 2D Ex tb IIIC T80 °C, T95 °C, T130 °C, T190 °C Gb. |
|
Degree of protection of a cover, IP |
IP66/IP67 |
|
Climatic performance |
F or NF or MU |
|
Operating temperature |
T6 – from -60 °C to +80 °C T5 – from -60 °C to +95 °C T4 – from -60 °C to +130 °C T3 – from -60 °C to +180 °C |
|
Switched current, A – alternating current, no more – direct current, no more |
800 |
|
Switched voltage, V – alternating current, no more – direct current, no more |
1000 |
|
Overall dimensions of shells, no more than, mm |
GUB without viewing window |
GUBX without viewing window |
120x120x115mm – code in designation 121211 151x151x125mm – code in designation 151512 175x175x130mm – code in designation 171713 235x235x164mm – code in designation 232316 277x277x218mm – code in designation 272722 430x430x291mm – code in designation 434329 |
175x175x130mm – code in designation 171713 235x235x164mm – code in designation 232316 277x277x218mm – code in designation 272722 430x430x291mm – code in designation 434329 |
|
GUB with viewing window |
GUBX with viewing window | |
120x120x107mm – code in designation 121210 151x151x113mm – code in designation 151511 175x175x120mm – code in designation 171712 235x235x146mm – code in designation 232314 277x277x195mm – code in designation 272719 430x430x235mm – code in designation 434323 |
175x175x130mm – code in designation 171713 235x235x164mm – code in designation 232316 277x277x218mm – code in designation 272722 430x430x291mm – code in designation 434329 |
|
Overall dimensions of a viewing window, no more, mm |
ø70x12mm – code in designation 007 ø90x15mm – code in designation 009 ø140x15mm – code in designation 014 ø160x19mm – code in designation 016 ø180x19mm – code in designation 018 ø230x19mm – code in designation 023 |
|
GUBX |
||
Housing material |
Stainless steel |
|
Ex marking |
I 2M Ex db I Mb; III 2D Ex tb IIIC T80 °C, T95 °C, T130 °C, T190 °C Gb. |
|
Degree of protection of a cover, IP |
IP66/IP67 |
|
Climatic performance |
F or NF or MU |
|
Operating temperature |
T6 – from -60 °C to +80 °C T5 – from -60 °C to +95 °C T4 – from -60 °C to +130 °C T3 – from -60 °C to +180 °C |
|
Switched current, A – alternating current, no more – direct current, no more |
800 |
|
Switched voltage, V – alternating current, no more – direct current, no more |
1000 |
|
Overall dimensions of shells, no more than, mm |
175x175x130mm – code in designation 171713 235x235x164mm – code in designation 232316 277x277x218mm – code in designation 272722 430x430x291mm – code in designation 434329 |
|
Overall dimensions of a viewing window, no more, mm. |
⌀70x12mm – code in designation 007 ⌀90x15mm – code in designation 009 ⌀140x15mm – code in designation 014 ⌀160x19mm – code in designation 016 ⌀180x19mm – code in designation 018 ⌀230x19mm – code in designation 023 |
Designation when ordering.
GUB | X , | X 1 X 2 … X n – | Y |
1 | 2 | 3 | 4 |
Enclosure Series: GUB – 434323 – 023.